Sunday, May 19, 2013
   
Text Size

12/24 BATTERY PACK

Great For Emergency Response or Routine Sampling!

Use 12V for long term sampling or 24V for High Volume Grab Sampling

 

12-24BATTERYPACK.jpg

 

2000 Peak Amps
Use at 12 volts
Use at 24 volts

Enough power to sample for a variety of situations

  • Heavy duty cable and slip connector or jumper cable clamps
  • Powered by two 12 volt sealed, lead-acid batteries
  • 12 volt systems use the batteries in parallel, 24 volt systems in series
  • DC outlet powers a variety of 12 volt accessories
  • Weighs 36 lbs. 16”Hx7”Dx12”W
  • Recharge from any 120 volt AC or 12V DC power supply; 12 volt charger is included

Power Without The Backache!

Power ANYWHERE!

  • Emergency lighting
  • Back-up power
  • Any 12 or 24v Device
  • Built in lighter style adapter

All Position Use

  • Sealed Lead Acid Genesis Battery won't leak
  • Transport, use or store in any position

Holds Charge for Months

  • Use test button to check for charge status

RADēCO tested the unit in two configurations under two different voltage selections.

Media
Voltage Selected
Start Air Flow
Finish Air Flow
Total Time Sampled

CP100/95% Paper (1)

12 VDC

1.36 CFM

.8 CFM

2 hrs 5 mins

CP100/95% Paper (1)

24 VDC

2.9 CFM

.8 CFM

1 hr 16 mins

Gelman AE 47 mm (1)

24 VDC

3 CFM

.5 CFM

1 hr 20 mins

 



 


 



Gelman AE 47 mm (2)

12 VDC

1.4 CFM

.6 CFM

3 hrs 45 mins

Gelman AE 47 mm (2)

24 VDC

2.8 CFM

1 CFM

1 hr 29 mins

(1) An H-809 DC was used.

(2) An H-810 DC was used.